Grass Comet Lab Based system (2009-present)

Channel EDF Label Input 1 Input 2 Sampling rate (Hz) Hardware filters (Hz) Sensor type
Left EOG E1 E1 M2 200 Low Pass 35 -
Right EOG E2 E2 M1 200 Low Pass 35 -
Left Frontal EEG F3_M2 F3 M2 200 Low Pass 35 -
Frontal EEG Fz_M2 Fz M2 200 Low Pass 35 -
Central EEG Cz_M2 Cz M2 200 Low Pass 35 -
Left Central EEG C3_M2 C3 M2 200 Low Pass 35 -
Parietal EEG Pz_M2 Pz M2 200 Low Pass 35 -
Left Occipital EEG O1_M2 O1 M2 200 Low Pass 35 -
Linked Center & Left Chin EMG cchin_l cchin_l - 200 Low Pass 70
Linked Left & Right Leg EMG lleg_r lleg_r - 200 Low Pass 70
ECG ECG ECG - 200 Low Pass 35
Snore snore snore - 200 Low Pass 70 Pro-Tech snore sensor
Airflow flow flow - 200 Low Pass 15 Dymedix disposible oral nasal airflow sensor
Nasal Pressure nas_pres nas_pres - 200 Low Pass 15 Pro-tech nasal pressure transducer
Thoracic IP thorax thorax - 200 Low Pass 15 Pro-Tech Z-Rip inductance plethysmography summation system
Abdominal IP abdomen abdomen - 200 Low Pass 15 Pro-Tech Z-Rip inductance plethysmography summation system
IP Sum sum sum - 200 Low Pass 15 Pro-Tech Z-Rip inductance plethysmography summation system
Position position position - 200 - Natus Neurology DC body position sensor
SpO2 spo2 spo2 - 200 - Ohmeda 3900 Oximeter with a 3 second averaging rate

Grass Heritage system (2000-2009)

Channel EDF Label Input 1 Input 2 Sampling rate (Hz) Hardware filters (Hz) Sensor type
Left EOG E1 E1 M2 100 Low Pass 30 -
Right EOG E2 E2 M1 100 Low Pass 30 -
Left Central EEG C3_M2 C3 M2 100 Low Pass 30 -
Left Occipital EEG O1_M2 O1 M2 100 Low Pass 30 -
Chin EMG chin chin - 100 Low Pass 30 -
Linked Left & Right Leg EMG lleg_r lleg_r - 100 Low Pass 30 -
Snore snore snore - 100 Low Pass 30 Microphone
ECG ECG ECG - 100 Low Pass 30
Nasal Airflow nasalflow nasalflow - 100 Low Pass 30 Thermistor
Oral Airflow oralflow oralflow - 100 Low Pass 30 Thermistor
Nasal Pressure nas_pres nas_pres - 100 Low Pass 30 Transducer
Thoracic IP thorax thorax - 100 - Respiratory inductance plethysmography
Abdominal IP abdomen abdomen - 100 - Respiratory inductance plethysmography
IP Sum sum sum - 100 - Respiratory inductance plethysmography
Position position position - 100 - Body Position
SpO2 spo2 spo2 - 100 - Oximeter